Quick answer: 5,000 ft/min is 25.4 m/s, not 18 m/s. Learn how tip speed is calculated, the pigment-specific speed bands and the viscosity window where a disperser stops working.
Key engineering takeaways
- 5,000 ft/min and 18 m/s are not the same number. 5,000 ft/min is 25.4 m/s; 18 m/s is about 3,540 ft/min. They are two different operating points, not two units for one specification.
- Tip speed is a result, not a setting. It is calculated from disc diameter and rpm: tip speed = π × D × N. A 300 mm disc at 1,000 rpm already runs near 18 m/s; quoting rpm without diameter is meaningless.
- The right number depends on the pigment. Published practice figures run from about 3,000 ft/min for difficult reds and violets to 5,000–5,500 ft/min for titanium dioxide. Hard-to-disperse pigments do not automatically need the highest speed.
- Viscosity sets the useful window. Saw-tooth dispersers work roughly from 1,000 to 50,000 cP; above that the vortex collapses and the disc slips instead of shearing. Higher viscosity needs a different tool, not more rpm.
- Use tip speed with D/T ratio and power. Tip speed alone will not predict dispersion. Disc-to-vessel diameter ratio and available motor power decide whether the energy reaches the whole batch.
- Verify on your paste. Ask for a material test that records disc diameter, rpm, tip speed, batch temperature and grind gauge — not a single headline number.
5,000 ft/min or 18 m/s? They are two different operating points
The short answer is that 5,000 ft/min and 18 m/s are not two ways of writing the same figure. One foot per minute is 0.00508 metres per second, so 5,000 ft/min converts to 25.4 m/s, while 18 m/s converts to roughly 3,540 ft/min. A buyer who asks for "5,000 ft/min or 18 m/s" is really asking which part of the disperser's speed range suits their product — and that is a pigment and viscosity question.
Both numbers are real and widely used. In published practice tables, saw-tooth dispersers run around 18–25 m/s for pigment deagglomeration, and pigment-specific guidance puts titanium dioxide near 5,000–5,500 ft/min while quinacridone reds and violets sit near 3,000–3,500 ft/min. The range exists because pigments differ in how their agglomerates break: some need high tip shear, some respond better to longer dwell time at a lower speed.
The practical trap is treating a number as a machine specification. A supplier who quotes "18 m/s" without stating the disc diameter has not told you anything you can reproduce, because tip speed is calculated, not dialled in. This guide sets out the calculation, the pigment and viscosity windows, and the questions that turn a headline figure into a usable specification.
There is a second reason to be careful with the two figures. They come from different measurement traditions — ft/min is common in older American disperser practice, while m/s is the standard unit in European and international equipment literature. A specification that mixes the two without converting invites a genuine engineering error, not just a translation issue. Converting once at the start of a comparison removes most of the confusion.
How tip speed is calculated — and why rpm alone is meaningless
Tip speed is the linear speed of the outer edge of the disperser disc. It is the product of the disc's circumference and its rotational speed:
Tip speed = π × D × N (D = disc diameter in metres, N = revolutions per second; result in m/s)
To convert ft/min to m/s, multiply by 0.00508. To convert m/s to ft/min, multiply by 196.85.
The consequence is immediate: the same rpm gives a completely different tip speed on a small laboratory disc than on a production disc. A 200 mm disc at 1,500 rpm gives about 15.7 m/s; a 400 mm disc at 750 rpm gives about 15.7 m/s too — same tip speed, half the rpm, twice the diameter. A purchaser comparing two machines on rpm alone could easily choose the wrong one.
This is why a useful quotation states disc diameter, rpm range and the resulting tip speed together. POLYC's single shaft high speed disperser and double shaft disperser are specified around the disc and drive together; the SDF550 laboratory disperser is the scale-down tool for measuring the same variables before committing to a production machine.
What the published pigment figures actually say
Practice tables tie tip speed to pigment type. The numbers below are published industry guidance, not a POLYC performance promise; treat them as a starting point for a trial, then measure your own result.
| Pigment type | Practice tip speed (ft/min) | Approx. m/s | Why it sits there |
|---|---|---|---|
| Titanium dioxide (white) | 5,000–5,500 | 25.4–27.9 | Relatively easy to wet; high speed breaks remaining agglomerates quickly |
| Carbon black | 4,500–5,000 | 22.9–25.4 | Strong agglomerates and high surface area need sustained shear |
| Phthalocyanine blue / green | 3,500–4,000 | 17.8–20.3 | Colour development is sensitive; excessive speed can damage the crystal and shift shade |
| Quinacridone red / violet | 3,000–3,500 | 15.2–17.8 | Lower shear protects colour strength and hue in an organic pigment |
Read the table carefully: the hardest-to-disperse pigment is not automatically the one at the highest speed. Organic pigments can degrade in colour or shift shade when over-sheared, so the acceptance criterion may be colour strength rather than the smallest possible particle. This is the same reasoning used in the pigment grinding guide — define what "good" means before choosing the operating point.
Note also that 18 m/s sits near the phthalocyanine and quinacridone band, not at the titanium dioxide band. When someone recommends "18 m/s" as a universal disperser setting, they are describing a mid-range operating point that happens to suit colour-critical organic pigments — not a rule for all pastes.
The viscosity window — where a saw-tooth disc stops working
A high-speed disperser does not grind by media; it creates a vortex that pulls powder into the high-shear zone at the disc edge. That mechanism has a hard viscosity limit. Published guidance places the saw-tooth disperser band around 1,000–50,000 cP and the tip-speed range near 18–25 m/s. Outside that band the machine either cannot form a proper vortex or cannot transfer shear into the bulk.
Below the window. In very thin liquid the disc can spin without developing enough shear to deagglomerate; power falls and the batch simply circulates. A different rotor geometry or a media mill may be more effective.
Above the window. As viscosity rises, the vortex collapses, the disc slips at the surface, and the material near the vessel wall barely moves. Adding rpm at this point raises temperature and power draw without improving dispersion. This is one of the most common causes of a disperser that "will not wet out" a high-viscosity batch.
The remedy is geometry, not speed. For higher viscosity, a coaxial sweep or double-shaft arrangement brings material back into the disc zone; the double shaft disperser and the disperser vs bead mill guide describe where that transition is useful. If the target is fine grinding in a stiff paste, a three roll mill is the appropriate tool — see the viscosity crossover guide.
Tip speed is only one of three variables
Tip speed predicts the shear at the disc edge. It does not predict whether that shear reaches the whole batch. Two other variables decide the result: the disc-to-vessel diameter ratio (D/T) and the power available at the shaft.
For saw-tooth dispersers a D/T ratio around 0.25–0.35 is typical. A disc that is too small relative to the vessel leaves dead zones near the wall; one that is too large can flood and lose the vortex. Motor power must be sufficient to hold the chosen speed under the actual batch viscosity — a machine that reaches its target rpm with an empty vessel may stall well short of it with a stiff paste.
| Variable | Typical range | What it controls | How to verify |
|---|---|---|---|
| Tip speed | 18–25 m/s for saw-tooth pigment dispersion | Shear intensity at the disc edge | Calculate from actual disc diameter and measured rpm |
| D/T ratio | ~0.25–0.35 for saw-tooth discs | How much of the batch reaches the shear zone | Measure disc diameter and vessel internal diameter |
| Motor power | Size to batch viscosity and solids loading | Whether speed is held under load | Record rpm and current draw at full batch |
| Batch temperature | According to formulation limits | Viscosity drift and pigment stability | Measure at start and end of the dispersion |
The table is a framework for your trial record, not a specification of any particular machine. Inline rotor-stator systems and triple-shaft mixers occupy different bands again; the pre-dispersing guide explains why poor upstream dispersion is a common cause of downstream bead mill problems.
From lab disc to production disc — what changes and what stays
One of the most common uses of tip speed is scaling a laboratory result to a production machine. The idea is sound: if both discs run at the same tip speed, the shear at the edge is in the same range. But the shortcut has limits, and understanding them prevents a disappointing scale-up.
What stays. Tip speed, D/T ratio and the pigment's acceptance criterion should be carried across. If a laboratory disperser reaches the target grind gauge at 20 m/s with a D/T ratio of 0.30, the production machine should be specified to reach the same tip speed with a comparable D/T ratio. That is the defensible part of the scale-up.
What changes. Batch volume, power per unit volume and heat removal do not scale linearly. A larger vessel has a lower surface-to-volume ratio, so the same tip speed can run hotter. A larger motor may have ample total power but less power per litre if the disc is not matched to the vessel. Dwell time at the shear zone also differs as the flow pattern grows.
How to handle it. Treat the laboratory result as a starting operating point, then re-measure on the production machine. Record tip speed, power draw and temperature together at each scale. The scale-up guide applies the same discipline to three roll mills: carry the process variables across, then verify rather than assume.
| Scale-up parameter | Laboratory disperser | Production disperser | What to re-verify |
|---|---|---|---|
| Tip speed | Set from the pigment trial | Match the same calculated value | Confirm rpm at full batch, not free-running |
| D/T ratio | Typically 0.25–0.35 | Keep in the same band where possible | Measure both diameters, do not assume |
| Power per volume | Often generous relative to batch | Can fall as volume grows | Record current draw and rpm under load |
| Heat removal | High surface-to-volume ratio | Lower surface-to-volume ratio | Measure temperature rise across the batch |
| Acceptance criterion | Grind gauge / colour strength | Same criterion, same test method | Confirm the result, not just the machine setting |
The table is a checklist, not a formula. It makes explicit the things that a tip-speed-only scale-up silently ignores. A supplier who can discuss all five rows is talking about a process; one who quotes only rpm is talking about a machine.
What the number cannot tell you — honest limits
Tip speed does not measure dispersion quality. It describes a machine condition, not a result. The result is the grind-gauge reading, the D90 and the colour strength on your paste. Two machines at the same tip speed can give different results if D/T ratio, disc condition, temperature or dwell time differ.
A higher number is not automatically better. Over-shearing can shift the shade of organic pigments, heat a temperature-sensitive vehicle, or simply waste energy. The pigment table above deliberately shows that several colours sit below 4,000 ft/min.
The unit convention does not change the physics. Whether a supplier quotes ft/min or m/s, convert before comparing. The inline disperser and the batch disperser are different machines; a tip-speed figure borrowed from one should not be applied to the other without checking the geometry.
Choosing an operating point — a decision rule
- Define the acceptance criterion. Grind gauge, D90 or colour strength — pick the measure that your customer actually judges.
- Identify the pigment family. Use the practice table as a starting band, not as a final setting.
- Measure viscosity at operating temperature. Confirm the paste is inside the disperser's window.
- Record disc diameter and calculate tip speed. Do not compare machines on rpm alone.
- Check D/T ratio and motor power. Make sure the speed can be held at full batch.
- Run a trial and log it. Record tip speed, temperature and grind gauge together, then choose the lowest speed that reaches the criterion consistently.
How to prove it before you buy — the material test
Ask for a trial on your own formulation that reports disc diameter, rpm, calculated tip speed, batch temperature and grind-gauge progress over time. Repeat at two or three speeds within the recommended band. The useful outcome is not the highest speed that works; it is the lowest speed that reaches your acceptance criterion with stable colour and acceptable temperature.
For a small-scale start, the SDF550 laboratory disperser lets you establish the relationship before scaling to a production machine. POLYC offers a material test and a configuration review so the choice rests on measured data rather than a quoted number. Request a test slot through the contact page.
Related reading: the pigment solutions and printing ink solutions pages describe where dispersion sits in the wider production line, from powder intake through to grinding and finishing. A disperser is usually the first stage of that line, and its result sets the load on every downstream machine — which is why a few hours spent defining the right tip speed is worth more than a larger motor specified on guesswork.
Frequently asked questions
Is 5,000 ft/min the same as 18 m/s?
No. Multiply ft/min by 0.00508 to get metres per second: 5,000 ft/min is 25.4 m/s, while 18 m/s is about 3,540 ft/min. They are two different operating points. The confusion comes from quoting practice figures from different sources as if they were one specification. Convert units first, then compare the pigment, viscosity and disc diameter behind each number.
How do I calculate tip speed from rpm and disc diameter?
Tip speed equals π multiplied by disc diameter in metres and rotational speed in revolutions per second. A 300 mm disc at 1,000 rpm gives about 15.7 m/s. Because diameter is part of the calculation, the same rpm produces very different tip speeds on different machines. Always state disc diameter, rpm range and resulting tip speed together in a specification, and confirm the speed is held under a full batch.
What tip speed should I use for titanium dioxide or carbon black?
Published practice guidance puts titanium dioxide around 5,000–5,500 ft/min (25.4–27.9 m/s) and carbon black around 4,500–5,000 ft/min (22.9–25.4 m/s). These are starting points, not promises. Organic pigments such as phthalocyanine blue and quinacridone sit lower, around 3,000–4,000 ft/min, because excessive shear can affect colour. Run a trial on your own paste and choose the lowest speed that meets the acceptance criterion.
Why does my disperser not wet out a high-viscosity batch?
A saw-tooth disc needs a vortex to pull powder into the shear zone, and that mechanism works roughly from 1,000 to 50,000 cP. Above the range the vortex collapses and the disc slips at the surface while material near the wall barely moves. Adding rpm raises temperature and power draw without improving dispersion. The remedy is a different geometry — a coaxial sweep or double-shaft machine — or a different process such as three roll milling.
Does a higher tip speed always give better dispersion?
No. Tip speed describes a machine condition, not a result. Above the speed that your pigment needs, you may gain nothing while shifting the shade of an organic pigment, heating a temperature-sensitive vehicle, or wasting energy. The right operating point is the lowest speed that consistently reaches your grind gauge, D90 or colour-strength target. Confirm it with a logged trial rather than a headline number.
Can I compare tip speed between a batch disperser and an inline mixer?
Only with care. The same tip speed can correspond to very different flow patterns because the geometry and residence time differ. Inline rotor-stator mixers, saw-tooth batch dispersers and triple-shaft mixers each have their own typical speed bands. Use tip speed as one variable alongside flow path, viscosity and dwell time, and verify on your formulation rather than transferring a number from one machine type to another.
Relevant POLYC MACHINE equipment
Related technical guides
Standards referenced
Method references used by process engineers when specifying and verifying the operations described in this guide.
- ISO 1524:2020 - Paints, varnishes and printing inks - Determination of fineness of grind
- ISO 13320:2020 - Particle size analysis - Laser diffraction methods