Calculate
Impeller diameter scales with the cube root of working volume, typically 0.8–0.95 of the container internal width. Motor power scales with volume and viscosity band, and rises with solids loading.
IBC Tank Mixer
An IBC is a container, not a mixer, and the mixer has to fit through the opening and still generate flow in a cube. Four answers place you in the right mixer type and shaft length.
Impeller diameter scales with the cube root of working volume, typically 0.8–0.95 of the container internal width. Motor power scales with volume and viscosity band, and rises with solids loading.
A 1,000 L IBC typically has a 150–225 mm top opening. Any impeller wider than that must fold, split or be inserted as a separate head. That constraint decides the mixer type before viscosity does: at high viscosity you need a wide paddle for mass transport, but the paddle must still get through the hole.
Folding blades solve the geometry but add a failure mode — hinges clog with product and blades that do not fully open produce a smaller effective diameter and a longer mixing time.
A cube-shaped container with a top-mounted shaft has poor circulation compared with a dished tank. Dead zones form in the corners, and a propeller that works in a 200 L drum may simply spin a column in a 1,000 L IBC. Off-centre mounting, a baffle or an axial-flow impeller with a draft tube makes a large difference to mixing time and to how much solid actually gets wetted out.
Yes, if the shaft and impeller are designed for quick transfer and the IBCs share the same opening and internal geometry. Clamp-on designs are common for this.
Typically 300–600 rpm with an axial impeller, enough to keep the surface moving. Higher speeds suspend more but also create vortexing and foam.
For wetting out powders, a rotor-stator head mounted through the opening works well. It cannot replace a bead mill for real particle size reduction.
Run a tracer test — a dye or salt — and sample at top, middle and bottom over time. If the bottom corner lags, add a baffle or change impeller pitch.