Tip speed v = πDN. Estimated shear rate ≈ v / (0.05D). Reynolds number Re = ρND²/μ, with ρ in kg/m³, N in revolutions per second, D in metres and μ in Pa·s.

Reading Reynolds number as an equipment signal

Below Re 10 the mixer is in laminar flow and the impeller cannot generate bulk circulation; mixing becomes a slow diffusion process driven by the blade surface. Between 10 and 1,000 the flow is transitional, and dead zones are the main risk. Above 1,000 a standard axial impeller produces turbulent bulk flow and mixing time depends on turnover rather than on diffusion.

Most IBC mixing problems come from running a propeller in the transitional band, where it neither pumps nor wipes the walls, and the answer is usually a larger impeller at lower speed rather than more power.

Shear rate is not the same as dispersion

A high shear rate at the blade tip breaks agglomerates locally, but only if the agglomerate passes through that zone. In a viscous product with poor bulk flow, most of the batch never visits the tip. That is why high-shear heads are mounted on a shaft that also generates flow, and why dispersing in an IBC works best with a combined axial and high-shear arrangement.

Frequently asked questions

Why does Reynolds number drop so fast when I increase viscosity?

Re is inversely proportional to viscosity. A ten-fold viscosity increase divides Re by ten, which can move a mixer from turbulent to transitional in one product change.

Should I increase speed or impeller size?

Increase diameter first. Pumping capacity scales with D³ against N, so a larger impeller at the same tip speed moves far more product for similar power.

What tip speed is safe in an IBC?

Around 3–5 m/s for axial impellers in mobile containers. Higher tip speeds risk vortexing, foam and shaft vibration in a cube-shaped tank.

Does density matter much?

It enters Re linearly, so a 1.8 g/cm³ product behaves as if it were less viscous than a 1.0 g/cm³ product at the same cP. It also increases shaft torque.