IBC Tank Mixer

Mixing Time Efficiency Calculator

Mixing time in a tank is a turnover problem: how long it takes the impeller to move the batch volume several times. This calculator uses the flow-number model to estimate minutes to 95% homogeneity.

Calculate

4
Pumping capacity—
Mixing time—
Turnovers per minute—
Note—

 

Pumping capacity Q = Nq × N × D³ (m³/s). Mixing time = turnovers × batch volume / Q. Turnovers per minute = Q / V × 60.

Turnover time versus shear time

Homogenising a liquid is about turnover: the batch must pass the impeller several times. Dispersing a powder is about both turnover and shear: the agglomerate must be transported to the high-shear zone and then stressed there. Mixing time from this model tells you the transport half; it says nothing about whether the shear was sufficient.

That is why adding a high-shear head to an IBC does not shorten the homogenisation time dramatically — it shortens the dispersion time for the fraction that passes through the head.

Why impeller diameter beats speed

Pumping capacity scales with D³ and linearly with N. Doubling the impeller diameter multiplies flow eight-fold at the same speed, while doubling speed only doubles flow and multiplies power by eight. Within the mechanical limits of the shaft and the opening, larger and slower is the efficient direction.

Torque, not power, is usually the limiting factor at low speed, so check the gearbox rating when you increase diameter.

Frequently asked questions

What flow number should I use?

0.5–0.6 for a pitched blade turbine, 0.7–0.8 for a marine propeller, and lower for high-viscosity paddles where axial flow collapses.

Is four turnovers enough for 95% homogeneity?

It is a common starting assumption. For miscible liquids three to five turnovers is typical; for solids suspension you need more.

Why is my measured mixing time much longer?

Most often dead zones in the IBC corners or a partially opened folding blade. Run a tracer test before changing the mixer.

Does viscosity change the mixing time?

Yes, strongly. Below the transitional regime the flow-number model stops working and mixing becomes diffusive, so times rise by an order of magnitude.